← Back to all lessons · Next: Transfer Function & Phase
sample rate ÷ FFT length. At 48 kHz with a 65536-point FFT: 0.73 Hz bin width. At 48 kHz with 8192 points: 5.86 Hz. Shorter FFTs are faster in real time but coarser at low frequencies. For RTA work where ⅔-octave grouping applies anyway, 4096 or 8192 points is adequate. For capturing sub-bass modal detail, use 65536 or higher.Nyquist theorem. A signal sampled at f_s Hz can be faithfully reproduced up to f_s⁄2. Frequencies at or above f_s⁄2 fold (alias) back below it. At 48 kHz, a 30 kHz tone aliases to 18 kHz. An audio interface's analog anti-aliasing filter must attenuate content above roughly half the Nyquist rate (24 kHz) well before the digital sampling clock. Most interfaces are well-specified, but a cheap interface with a poor AAF will produce spectral artifacts that appear in the FFT as spurious low-frequency peaks. If you see repeating "ringing" structures at specific frequencies in a capture, suspect AAF distortion before suspecting the room. The remedy is increasing sample rate (48 → 96 kHz) which raises the Nyquist cutoff and eases the AAF's job — but only if the interface's AAF bandwidth permits it. A 96 kHz interface may still have an AAF that rolls off at 38 kHz; a 48 kHz interface with a good AAF is often more faithful at 40 kHz than a cheap 96 kHz unit. Always verify with the Captured view before trusting a frequency response plot.
Windowing and frequency resolution — why 10 ms ≠ 100 Hz simply. A rectangular window of duration Δt has a first null at 1/Δt in frequency domain. But the usable resolution (first null from centre, i.e. the half-width of the main lobe) is 1/(2Δt) for rectangular, roughly 1.1/Δt for Hann, etc. In REW the "window duration" in the window dialog refers to the total selected width (left + right), so for a symmetric window of total 10 ms, the resolution is approximately 100 Hz. The frequency-dependent window (FDW) used in REW adjusts width per frequency bin: at high frequencies the window is short (high time resolution, low time-domain information), at low frequencies it is long (low time resolution, good frequency detail). FDW is the default and is correct for almost all room measurements. If you disable FDW and use a flat rectangular window across all frequencies, your low-frequency resolution improves but your high-frequency resolution degrades significantly (you will lose phase detail above ~2 kHz), which is almost never desirable for speaker or system measurement. For room-only work at low frequencies, FDW or a simple rectangular window with sufficient total length both work; for measuring a loudspeaker's own frequency and phase response, keep FDW on.
When to use which FFT size in practice. RTA live view: 4096 points (48 kHz → 11.7 Hz bin width, but RTA groups into ⅓-octave anyway). Room mode identification (40–120 Hz): 65536 points (0.73 Hz/bin). Subwoofer alignment measurement (sub to main, low-freq focus): 65536 or 131072. Full-range speaker measurement (20 Hz – 20 kHz) with smooth phase: 65536 points is typically sufficient. RTA at 48 kHz and 4096 points groups into ⅓-octave bins which average over ~100 bins at low frequencies; you do not need a 65536-point FFT for live EQ decisions — the RTA smoothing already integrates out individual bin noise. This is a key reason RTA is useful: it is robust to low averaging counts because the octaves themselves average the spectrum.
Q1: At 48 kHz with a 10 ms total window, what is the approximate lowest resolvable frequency?
A1: Approximately 100 Hz (1 ÷ 0.010 s).
Q2: You are measuring a 30 Hz mode in a room. Why is a 10 ms window insufficient?
A2: 10 ms gives a 100 Hz resolution floor; the 30 Hz peak cannot be represented in a bin narrower than ~100 Hz, so it would appear smeared or absent in the frequency response. Use a ≥ 35 ms window (33 Hz or better) for reliable sub-40 Hz measurement.
Q3: The captured view shows a clean sine sweep but the RTA shows a "hole" at 4 kHz. What is the first thing to check?
A3: Whether the hole is a standing-wave cancellation (frequency stays stable when mic moves slightly) versus an AAF/resonance artifact (does not move with position). AAF artifacts in a capture would also show up as non-sinusoidal features in the Captured waveform; a room null would show consistent peak/dip structure in the ETC.